The Sensor Link input node provides the absolute, relative and delta values of the Sensor Link device - the encoder inputs, the analog 0-10V inputs and the switch states 1 to 8.

_img786

Node Properties:

Please enter the Sensor Link IP and Port number.
Connect the WD with the Sensor Link.

E1 Range:
Enter the encoder's amount of steps. If the encoder provides 1440 steps, enter 1439 because the counting starts with zero.
Please note that the encoder's range has to be entered in the SensorLink Configuration Tool, too.

E2 Range:
Enter the encoder's amount of steps. If the encoder provides 1440 steps, enter 1439 because the counting starts with zero.
Please note that the encoder's range has to be entered in the SensorLink Configuration Tool, too.

E1 Relative:
Enter zero to reset the relative step count for the current encoder position or enter an offset value.

E2 Relative:
Enter zero to reset the relative step count for the current encoder position or enter an offset value.

The Node generates the following output:

- E1,

- E2,

- Analog 1,

- Analog 2,

- Switch 1,

- Switch 2,

- Switch 3,

- Switch 4,

- Switch 5,

- Switch 6,

- Switch 7,

- Switch 8,

- E1 Delta,

- E2 Delta,

- E1 Relative,

- E2 Relative,

- Link Connection State.