(P/N 1012 –PhidgetInterfaceKit 0/16/16)

The Interface Kit 0/16/16 allows receiving the status of 16 Digital Inputs sensing up to 30 VDC and controlling 16 Digital Outputs up to 30 VDC.

_img1034

Setting up the digital inputs

The Digital Inputs are activated by an external voltage source, triggering on a wide voltage range - 4 to 30VDC. Depending on the status of the digital inputs dedicated scripts may be executed. To do so enter the commands in the On-Script and Off-Script text fields. The colored box in front of each input displays the input status: ON = green, OFF = white. The topic Script Language explains commands and how to use them in more detail.

Tick the check box [Enable Scripts] to enable the On- and Off Scripts.

To enable or disable the execution of a script triggered by the digital inputs via a command (e.g. by clicking a Custom Script Button), use these commands, you can as well control the outputs via commands.

Setting up the digital outputs

Each digital output you want to use needs to be enabled by ticking the check box according to the output.